Inventory, the Kingston storage alerts, the sheet register, and the PPE on the same hazards.

Hazardous Substances36
Five are listed
Storage Alerts3
Incompatible, threshold, expired sheet
PPE Expiring6
The harness and the respirator
Inventory
SUB-014 is the electrolyte at Mandeville. SUB-030 is the diesel at the Kingston generator, over its threshold.
0 selected
Substance IDSubstanceLocationQuantityUnitClassificationSDS VersionStorage ClassExpiryStatus
SUB-014Battery electrolyteMandeville POP40LCorrosiveSDS-014 v3801 Jun 2027In use
SUB-018Isopropyl alcoholKingston Head-End18LFlammableSDS-018 v2301 Mar 2027In use
SUB-022DieselMontego Bay POP400LFlammableSDS-022 v1301 Dec 2027In use
SUB-026Oxidising cleanerKingston Head-End12LOxidiserSDS-026 v15.101 Jan 2027Incompatible Storage
SUB-030DieselKingston Head-End800LFlammableSDS-030 v4301 Sep 2027Threshold Breach
Compatibility
Kingston stores the oxidiser in the same room as the diesel. The diesel quantity is 800 L against a 500 L threshold.
LocationSubstanceStorage ClassCompatible WithIncompatible WithQuantityThresholdThreshold StatusAlert
Mandeville POPBattery electrolyte8Class 8 onlyClass 3, class 5.140 L100 LWithin limit—
Kingston Head-EndIsopropyl alcohol3Class 3Class 5.118 L20 LWithin limit—
Kingston Head-EndOxidising cleaner5.1None in this roomDiesel, isopropyl alcohol12 L20 LWithin limitIncompatible Storage
Kingston Head-EndDiesel3Class 3Class 5.1800 L500 LThreshold BreachThreshold Breach
PortmoreSolvent degreaser3Class 3Class 5.16 L20 LWithin limitExpired
Safety data sheets
SDS-014 v3 is current for the electrolyte. SDS-040 is expired. SDS-018 v1 is superseded by v2.
SDS IDSubstanceVersionIssue DateEffective DateSuperseded DateLocationOwnerStatus
SDS-014Battery electrolytev301 Feb 202601 Feb 2026—Mandeville POPAP Andre PowellCurrent
SDS-018Isopropyl alcoholv201 May 202601 May 2026—Kingston Head-EndOR Omar ReidCurrent
SDS-018Isopropyl alcoholv101 May 202401 May 202401 May 2026Kingston Head-EndOR Omar ReidSuperseded
SDS-036Dieselv401 Nov 202301 Nov 2023—Kingston Head-EndDC Damian ClarkeExpiring
SDS-040Solvent degreaserv101 Jan 202201 Jan 2022—PortmoreLC Leroy CampbellExpired
PPE
Keisha Morgan’s insulated gloves are the pair named on RA-014. Damian Clarke’s harness inspection is due.
PPE IDWorkerHazardPPE TypeIssue DateInspection DueExpiryFit TestFit Test DateStatus
PPE-014KM Keisha MorganElectrical energyGloves01 Mar 202601 Dec 202601 Mar 2027——Issued
PPE-015KM Keisha MorganOptical workEye Protection01 Mar 202601 Mar 202701 Mar 2028——Issued
PPE-018DC Damian ClarkeWorking at heightSafety Harness01 Jun 202512 Oct 202601 Jun 2027Pass01 Jun 2025Expiring
PPE-022AP Andre PowellElectrolyteProtective Clothing15 Jan 202615 Jan 202715 Jan 2028——Issued
PPE-026LC Leroy CampbellDustRespirator01 Feb 202501 Aug 202601 Feb 2026Pass01 Feb 2025Overdue

Class 8. Kept out of the Kingston flammable room. SDS-014 v3.

Class 8 is stored on its own at Mandeville. The Kingston alert is a different room.

SDS-040 passed its review date and has no successor on the shelf at Portmore.

These gloves are the insulated gloves named on SP-014, RA-014 and PTW-014.