Routing & Work Centres — NexavionERP
Product Lifecycle & Engineering/Routing & Work Centres
Ana Kowalski
ana@meridianco.com
Log Out

Routing & Work Centres

The routing revision stays with the BOM revision

Active Routings318
Aligned to a BOM revision
Work Centres46
Kingston and Montego Bay
Alternate Routings27
▲ 1 this month
Routings
RT-ONT-14 Rev C is effective 12 Aug 2026, the same date as BOM-ONT-14 Rev C.
0 selected
Routing IDProductRevisionBOM RevisionEffectivityOperationsWork CentreStatus
RT-ONT-14ONT Starter KitCC12 Aug 20264WC-OPTActive
RT-FBR-4848-core fiber cableBB03 Mar 20263WC-REELActive
RT-SIM-100SIM Starter PackAA18 Jun 20262WC-PACKActive
RT-CPE-22Outdoor CPEBB—4WC-OPTIn Review
No records match this filter.
Routing and BOM effectivity aligned
ONT Starter Kit Rev C
BOM-ONT-14 Rev C and RT-ONT-14 Rev C · 12 Aug 2026Aligned
Operations · RT-ONT-14 Rev C
Times are the controlled standard. Nothing is scheduled from this screen.
OperationSequenceWork CentreSetup TimeRun TimeTeardown TimeRequired SkillsRequired ToolsActivity Type
Kitting10WC-KIT15 min6 min4 minStores clerkReel trolleyLabour
Optical fit20WC-OPT20 min12 min5 minFibre technicianFusion splicerMachine
Inspection30WC-QA5 min8 min2 minQA inspectorPower meterInspection
Pack40WC-PCK5 min4 min3 minPackerCarton jigLabour
No records match this filter.
Work centres
46 work centres on the book. Rates are displayed only.
Work CentreDescriptionLocationCapacitySkillsToolsCost RateStatus
WC-KITKitting cageKingston Main Warehouse2 benchesStores clerkReel trolleyJMD 1,850/hActive
WC-OPTOptical benchKingston Main Warehouse3 benchesFibre technicianFusion splicerJMD 3,200/hActive
WC-QAInspection bayKingston Main Warehouse1 bayQA inspectorPower meterJMD 2,400/hActive
WC-PCKPack lineKingston Main Warehouse2 stationsPackerCarton jigJMD 1,600/hActive
WC-REELReel yardKingston Main Warehouse1 yardCable techReel standJMD 2,100/hActive
WC-MOBField kittingMontego Bay Depot1 benchField techVan kitUSD 42/hActive
No records match this filter.
Alternate routings
27 alternates on the book. The lot-size rule selects RT-ONT-14-A when the batch is above 50.
ProductRoutingSelection RuleLot SizeCapacity ConditionCost ConditionStatus
ONT Starter KitRT-ONT-14Primary1 to 50Kingston benches openStandardActive
ONT Starter KitRT-ONT-14-ALot SizeAbove 50Montego Bay bench freeLower costSelected
48-core fiber cableRT-FBR-48-SCapacity AvailableAnyReel yard fullStandardStandby
No records match this filter.
Selected routing
Static example for a batch of 80 ONT Starter Kits
Lot size above 50RT-ONT-14-A selected
Nexavion AI● Online
Ask about anything in Product Lifecycle — try: